Posted on Tuesday June 03, 2025
Successful exploitation of this vulnerability could allow an attacker to inject code or bypass authentication.
The following Schneider Electric products are affected:
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Out-of-bounds Write, Download of Code Without Integrity Check vulnerability in Silicon Labs Gecko Bootloader on ARM (Firmware Update File Parser modules) allows Code Injection, Authentication Bypass. This issue affects "Standalone" and "Application" versions of Gecko Bootloader.
CVE-2023-4041 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2023-4041. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
Schneider Electric reported this vulnerability to CISA.
The Wiser AvatarOn 6K Freelocate and Wiser Cuadro H 5P Socket products have reached their end of life and are no longer supported. Users should immediately either disable the firmware update in the Zigbee Trust Center or remove the products from service to reduce the risk of exploitation.
To stay informed about all updates, including details on affected products and remediation plans, subscribe to Schneider Electric's security notification service here: https://www.se.com/en/work/support/cybersecurity/securitynotifications.jsp
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.